Neurosurgical review
Complication rates and functional outcomes following endoscopic endonasal optic canal and orbital apex decompression procedures for non-traumatic optic neuropathy: a systematic review and single-arm meta-analysis
By Gupta K, Altschul D, Pahlevani M and 2 others.
Abstract
To quantify functional outcomes and complication rates following endoscopic endonasal optic nerve decompression (EOND), a spectrum of related procedures, for non-traumatic optic neuropathy (NTON), and to identify sources of variability in the published evidence.
Systematic review and single-arm meta-analysis following PRISMA 2020. Five databases were searched to April 2025 for outcomes after endoscopic endonasal decompression of the optic canal, orbital apex or medial orbit. Proportions were pooled with a random-effects inverse-variance model on the logit scale (REML); sparse safety events with exact binomial intervals. Subgroups were defined by aetiology and surgical corridor. Risk of bias used an item-level Newcastle-Ottawa Scale, and certainty of evidence GRADE.
Seventeen studies (356 patients, 437 treated eyes or optic nerves) were eligible. Across 14 studies (364 analytic units), pooled improvement in visual acuity or optic nerve function was 78% (95% CI 65-87), with substantial heterogeneity (I² 78%) and a wide prediction interval (27-97%). Aetiology accounted for most of this: 95% (91-97) in dysthyroid optic neuropathy, 63% (46-77) in raised intracranial pressure and 59% (40-76) in neoplastic or compressive disease (p < 0.001), I² 0-42% within strata. Among 6 studies (135 units) with formal perimetry, visual field improvement was 77% (69-84; I² 0%). New-onset diplopia was bimodal: 25% (11-45) where orbital fat was removed versus 6% (2-14) where it was not (p = 0.016). Severe complications occurred in 5 of 311 patients (1.6%, 0.5-3.7).