Journal of Clinical Medicine
High-Flow Nasal Oxygen and Desaturation During Deep Sedation for Colonoscopy in Patients at Increased Respiratory Risk: A Propensity Score-Matched Cohort Study
By M. Ángeles Alonso-Fernández, Óscar Martínez-Nieto, Monica Garcia‐Alonso and 9 others.
Abstract
Background/Objectives: Hypoxaemia is the most common adverse event during procedural sedation. High-flow nasal oxygen (HFNO) may reduce desaturation through continuous positive airway pressure, anatomical dead space washout, and stable FiO2 delivery. This retrospective cohort study assessed the association between two oxygen delivery strategies—HFNO versus Venturi mask oxygen—and the incidence of desaturation (SpO2 <90% at any time) during deep sedation for colonoscopy in patients at increased respiratory risk. The two strategies differed simultaneously in flow rate, delivered FiO2 (0.50 vs. 0.40), device interface, and humidification; any observed difference cannot be attributed exclusively to the high-flow mechanism.
Methods
A single-centre retrospective cohort study with propensity score matching (PSM) was performed, including 200 consecutive adult patients with established obstructive sleep apnoea (OSA) or high-risk STOP-BANG criteria undergoing deep sedation for colonoscopy, grouped by oxygen delivery strategy: HFNO via nasal cannula (50 L/min, FiO2 0.50) versus Venturi mask (12 L/min, FiO2 0.40). The estimand of interest was the average treatment effect on the treated (ATT).