Hernia : the journal of hernias and abdominal wall surgery
Impact of slit versus non-slit mesh on recurrence after inguinal hernia repair: a systematic review and meta-analysis
Von Mulhall CB, Danh N, O'Kelly R und 4 weiteren.
Inhalt auf Englisch
Abstract
Inguinal hernia repair is among the most frequently performed operations worldwide, and durable mesh-based repair is the standard of care. During laparo-endoscopic repair, surgeons choose between slit and non-slit mesh to accommodate the cord structures, yet the optimal configuration remains uncertain. We aimed to determine whether slit mesh, compared with non-slit mesh, reduces recurrence without increasing chronic groin pain or mesh-related complications.
We searched Embase, PubMed and Scopus for comparative studies of slit versus non-slit mesh in adults undergoing inguinal hernia repair. Randomised controlled trials and prospective or retrospective comparative cohorts were eligible. Two reviewers independently screened records, extracted data and assessed risk of bias using Cochrane RoB-2 and the Newcastle-Ottawa Scale, with certainty rated using GRADE. Dichotomous outcomes were pooled as odds ratios (OR) and continuous outcomes as mean differences (MD), using random-effects models with restricted maximum likelihood (REML) estimation as the primary analysis. Sensitivity analyses used the DerSimonian-Laird and Hartung-Knapp-Sidik-Jonkman (HKSJ) estimators, the latter recommended when few studies contribute to an outcome. Recurrence was also analysed by study design, by leave-one-out analysis and using adjusted effect estimates where available. Heterogeneity was quantified with the I2 statistic.