Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery
Three-dimensional versus conventional miniplates in the management of mandibular angle fractures: A systematic review and meta-analysis
Von Rashid S, Kumar RD, Choudhary S und 3 weiteren.
Inhalt auf Englisch
Abstract
Mandibular angle fractures are common injuries associated with a relatively high rate of postoperative complications, and their management remains biomechanically challenging. Three-dimensional (3D) miniplates have been introduced as an alternative to conventional two-dimensional (2D) miniplates, with the aim of improving stability; however, their clinical superiority remains uncertain. This systematic review and meta-analysis aimed to compare the outcomes of 3D and conventional miniplates in the management of mandibular angle fractures. A comprehensive search of PubMed, Embase, Scopus, ScienceDirect, and the Cochrane Library was performed up to 15 March 2026, supplemented by manual searches and trial registries. Randomized controlled trials and comparative studies evaluating 3D versus 2D miniplates were included. Data extraction and risk of bias assessment were performed independently by two reviewers using the Cochrane RoB 2 and ROBINS-I tools. Meta-analysis was conducted using a random-effects model, and certainty of evidence was assessed using the GRADE approach. Eighteen studies were included, comprising 10 randomized controlled trials, 3 prospective studies, and 5 retrospective studies. Pooled analysis demonstrated no statistically significant differences between 3D and 2D miniplates in postoperative infection (log risk ratio -0.93; 95% CI: -2.11 to 0.25), malocclusion (log risk ratio -0.80; 95% CI: -2.04 to 0.45), wound dehiscence (log risk ratio -0.68; 95% CI: -1.72 to 0.37), hardware failure (log risk ratio -1.10; 95% CI: -3.26 to 1.06), or hardware removal (log risk ratio -0.35; 95% CI: -2.32 to 1.61). Operative time also showed no significant difference (mean difference -2.65 min; 95% CI: -7.42 to 2.13), with substantial heterogeneity (I2 = 81.5%). The certainty of evidence ranged from low to moderate, primarily due to risk of bias and imprecision. Current evidence indicates that 3D miniplates do not confer a significant clinical advantage over conventional miniplates in mandibular angle fractures. Both systems demonstrate comparable outcomes, and treatment choice should be individualized. Further high-quality, adequately powered randomized trials with standardized outcome reporting are required to establish definitive clinical recommendations.



